Sr trace deicing cable pdf

A full complement of accessories allows roof, gutter, downspout deicing and pipe tracing applications. The selfregulating heating cable automatically varies its heat output as the surrounding temperature changes. The sr trace roof and gutter deicing cable is available. The cables selfregulating heat output provides additional benefits. Dsh downspout hangers support the heater cable descending a.

Complete electric heat tracing system a complete electric heat tracing system will typically include the following components1. Because of the selfregulating feature of this cable, it can be wrapped over itself overlapped, if necessary, when installed on pipes, valves or flanges. Preassembled selfregulating cable installation manual. Because of this, the sr trace can be overlapped, minimizing the risk of damaging temperaturesensitive roof coating. Sr self regulating heating cables are used in many applications, residential, commercial, and industrial. Sr cables have a conductive core that reacts to the surrounding temperature. The sr trace roof and gutter deicing cable is available with a power density of 5 watts per foot dry and 8 watts per foot wet. They are suitable for use on asphalt or wood shingles, metal roofing or membrane type roofing and downspouts that freeze and clog. Roof and gutter deicing, selfregulating, cuttolength. Prevents dangerous icicles from building up over pathways and doors.

The heating cables are configured for use in nonhazardous and hazardous classified locations, including areas where corrosives may be present. Examples of types of roof heat cable to prevent ice dams on roofs and rain gutters. Schematics roof deicing dwg schematics roof deicing pdf. The adks cable plugs into a standard 120 vac gfci protected threewire grounded outlet.

Sr series selfregulating pipe trace freeze protection heating cable is designed for a variety of pipe freeze protection applications. The cable is constructed so that it will not burn out or overheat when overlapped, and can be used on metal and plastic pipes. Sr51j250 easy heat sr51j250 250 ft reel of 120 vac sr. Watch our video to find out how to effectively combat ice dams for your complete winter solution. Easy heat cks12 roof deicing cable spacers and clips kit. Roof heat cable, heat trace, or ice melt cable types. How to hardwire a selfregulating heat cable into a junction box, with a tutorial of the final end seal. For straight tracing, install the heating cable on a the lower. The deicing cable is easy to install given that the manual has clear and detailed instructions. Low temperature self regulating cable without aluminum tape. Commercial selfregulating cable for roof deicing or pipe tracing. Table 1 wintergard wet heating cable length for roof deicing eave overhang1 distance tracing2 width tracing2 height length of heating cable per foot of roof edge. Optional indoor manual control interfacesfmc receiver.

Electric solutions to sr trace installation and cold. So, if you need attic insulation and are having ice dams start with the deicing cable cheaper then get more insulation blown into your attic. Detecting cable damage prior to the application of insulation can prevent additional labor costs. Pipe and roof deicing heating cable installation instructions. Colder temperatures draw more current and more wattage. Disconnect cable from performed at the factory after receipt at job site after cable install. Before tracing pipes after installing terminations. They are ideal for use on commercial metal or plastic water supply and drain pipes subject to freezing. How to make a roof and gutter deicing cable power connection. Wet location pipe cable sold by the foot and cut to length. Easyheat from deicing and pipe freeze protection to. Looking for a costeffective and easytoinstall heat trace system.

Sr trace cables are generally suitable for use on asphalt or wood shingles, metal roofing or membrane type roofing. King offers a wide range of electric heating cable. Self regulating heater cable easyheat sr trace heating. Sr trace is a selfregulating heating cable that automatically varies its heat output with changes in surrounding temperature. Roof deicing heat trace cable rhsrr and rhsrl data sheet. It is very effective to deice the snow on the roof. Apply anywhere melting snow and ice can refreeze and penetrate roof surface causing leaks and related damage.

If you need to maintain proper pipe temperatures in applications that range from residential freeze protection to commercial maintenance flowcontrol processes, rely on the proven performance of easyheat pipe tracing products. Edgecutter aluminum roof deicing flashing is used with selfregulating heat ing cable to aid in keeping snow and ice. The adks deicing cable is installed over the unheated portions of the roof above the overhang or into gutters or downspouts to create an icefree pathway for melting water to drain. Electric heat tracing, heat tape or surface heating, is a system used to maintain or raise the temperature of pipes and vessels using heat tracing cables. End terminations should not be located in an area where moisture is present. The cable is available in 100 and 250 foot coils and also 500 and 1,000 foot reels. Ice can wreak havoc on homes and businesses if left unattended, but you can be proactive and protect your investment with effective heat trace systems from heat trace specialists. Easyheat sr trace selfregulating freeze protection cable. Also look here to find easyheat roof and gutter deicing products, engineered to protect properties from the damage caused by ice dam formations. Sr trace accessories zhc roof clips are used for all types of installations. The accessories that came with the package spacers and clips are sufficient for my case without having to order an additional spacer and clip kit. Standard 46 gutters use 1 run of heat trace cable in gutter.

At warmer temperatures, the cable current and wattage tapers back, thus saving energy. Inline splices and tee splices should be avoided where 2. Heating cableheating cable testing procedures september 1 2010september 1, 2010 september 2010 1 company confidential service strategy 1. Xarex xgr self regulating roof gutter deicing heating cable 50ft preassembled. Our smart heating cable solutions include deicing, pipe freeze protection, snow melting and comfort floor warming applications. Labels, installation manual, roof clips, hanger brackets and uv resistant cable ties. Pipe and roof deicing heating cable installation instructions psr heating cable may be used to prevent water pipes from freezing or to prevent the formation of ice dams on roofs. The cable reduces its power output as the ice and snow. Easyheat selfregulating heating cable is a selfregulating heating cable that provides maximum freeze protection for pipe lines and vessels. Follow the instruction manual to design an installation plan and purchase. Heating cableheating cable testing procedures september. Dsh downspout hangers support the heater cable descending a downspout drain.

Roof and gutter deicing hsr mi trace pipe tracing controls roof and gutter deicing product selection guide 47 adks cable 48 x psr cable 53 x x sr trace cable 55 x x sr trace accessories 59 x x pipe tracing accessories adks crankcase heaters roof and gutter deicing controls 60 x x snow melting snow melting product selection guide 64 sno. Guttermelt heat trace cables from heatizon heatizon systems. Pdf easyheat sr trace heating cables self regulating heater cable. For gutter deeper than four inches, additional cable will be needed, contact pentair thermal management at 800 5456258. Sold by world class heat trace cables and fulfilled by amazon. This is a custom order which cannot be cancelled or returned.

Easyheat sr trace cable is a selfregulating heating cable that provides maximum freeze protection for pipe lines and vessels. Data sheet heat trace cable data sheet heat trace document roof heating document selfreg data sheet. Sr heating cable design for roof and gutter applications design notes. Use the sr trace to prevent pipes from freezing, to maintain liquids in a pipe at a constant temperature or to maintain viscosity for flow conditions. Whether the application is a small project or a complete network of piping and equipment, designing an electric heat tracing system for complex piping is simplified by using thermon selfregulating cables.

Selfregulating cables for the roof and gutter heating, melt snow and ice to keep a. Xarex xgr self regulating roof gutter deicing heating cable 50ft. Selfregulating heating cable product information easy heat sr. This selfregulating cable provides the right amount of heat when and where it is needed. Download the rhsrr and rhsrl heat trace cable data sheets pdf heat trace document roof heating document selfreg cable document. Electric heat tracing cable2 selfregulating, power. Cables are available for 120, 240, 208, or 277 vac applications.

Series heating cable output and trating are dependent upon several variables, including supply voltage, cable resistance, and temperature conditions. Trace heating cable testing selfregulating cable a test should be performed when the heating cable is received, prior to installation and after installation using a 500 vdc megger. For selfregulating heating cable introduction this design guide addresses the heat tracing requirements of complex piping. Easyheat sr trace heating cables are used in frost protection and deicing applications to prevent costly damage to residential and commercial guttering and roofs. Roof heat cable, heat trace, or ice melt cable types youtube. Because of this, the sr trace can be overlapped, minimizing the risk of. Heating cable systems are designed to protect against coldrelated problems throughout your home and business. Psr heating cable is suitable for use on metal and plastic pipes such as pvc or polybutylene but not on flexible vinyl tubing such as garden hose. Do not attempt to repair the damaged heating cable section. Selfregulating heating cable product information principle of operation sr trace selfregulating heating cables automatically vary their heat output with changes in surrounding temperature. Self regulating heater cable easyheat sr trace heating cables. This could be caused by ice formation or accumulation of snow in roof valleys, gutters which are prone to icedamming and dangerous icicles and also downspouts that freeze and clog. Heating cable in downspouts should be looped and extend below the frost line if tied into a drainage system. Sr heating cable design for roof and gutter applications.

E asyheat psr preterminated selfregulating freeze protection cable for water pipes and roofs wrapon roof and gutter heating cables. Raychem icestop installation and operation manual for roof. Easyheat sr trace heating cables are used in frost protection and deicing applications to prevent costly. Sr trace roof and gutter deicing cable prevents costly damage to roofs caused by ice formation and snow accumulation in gutters, downspouts, and roof valleys. Watch this warmlyyours tech tip and learn the proper way to test snow melting mats and slab heating cable. Sr trace is rated at 5 watts per foot 8 watts per foot wet, and automatically varies its heat output with changes in surrounding temperature. The etpwrkit is culus listed and is suitable for use with et sr series cables. As described on page 3 downspout ending in a drain the heating cable should extend into the heated area or below the frost line. Easyheat sr trace cable roof and gutter deicing, selfregulating, cuttolength. Sr trace is a parallelresistance, selfregulating, cuttolength cable. Sr trace can also be used in roof and gutter deicing. Easyheat, your industry leader in pipe freeze prevention and roofandgutter deicing applications, introduces psr preterminated selfregulating cable.

589 495 937 314 693 344 145 36 899 752 348 907 683 423 672 229 315 881 433 1365 1467 644 1299 1452 787 499 608 1166 853 287 950 849 15 992 728 62 1063 885 441